parameters

• Input voltage range: single-phase 195~245V three-phase 340V ~ 420V
• Input frequency range: 50/60Hz ± 5%
• Output voltage range: single-phase 0~300V (0~600V optional) three-phase 0~520V (0~1040V optional)
• Output frequency range: 45~500Hz
distortion rate ≤ 0.3 voltage stabilization rate ≤ 0.5 frequency stability ≤ 0.01%
the three-phase phase angle can be adjusted (0~120). In use, each phase can independently adjust the voltage and frequency, and it can independently display the voltage and frequency linear climb and drop editing test functions. It can do the gradual change and interruption test of voltage and frequency, and has the independent compensation function of impedance, which can simulate various test and test grid power supplies.

High performance characteristics
• Low distortion interference, complete input/output isolation
• Single-phase maximum capacity up to 20KVA, three-phase power up to 60KVA
• Remote voltage feedback function to ensure that the test point voltage value is consistent with the set value
Voltage, current measurement using high-precision ADC AC sampling, digital true value calculation
• Using single chip microcomputer (D/A circuit) to directly collect voltage and current waveform data. With RS232 or RS485 interface, can communicate with the computer
• Built-in soft start device, can easily start the motor, compressor and other high starting current load
• The use of central processor design, control the opening and closing of the logic circuit. The use of one-to-one drive method is conducive to the dispersion of heat dissipation of power parts, the structure is conducive to "redundant" design.
The internal temperature and humidity of the machine are detected, and the intelligent exhaust and dehumidification are carried out in the wet return to the south to ensure the normal use of the power supply.

humanized design
• LCD display parameters: voltage, frequency, power, power, current, peak current and time
• LED display voltage, current, frequency, power (power factor)
A single test group can perform 35 test points (different voltage 0~300V, frequency 45~500Hz, time 0.1S ~ 999.9H setting), and can continuously do cyclic tests (0~999999 times).
Power multi-point real-time sensor monitoring, normal operation code and fault code screen display, full control of power supply status
• Parameter calibration is completed by open software, which is different from other power supplies. Potentiometers and adjustable resistors are also adjusted on the circuit.
• Wide voltage and frequency adjustment range, digital key input, independent display of three-phase voltage and line voltage
Digital password lock, test data security and can prevent important test data from being modified by misoperation

APA1000L single phase series

Model1000L1001L1002L1003L1005L1010L1015L
Output capacity500VA1KVA2KVA3KVA5KVA10KVA15KVA
Input1Ø2W+G 110V/220V±10% 220V±10% 50/60Hz±5%
Output frequency50Hz 60Hz 45~500Hz
frequency stability0.01 percent
Output voltage0~150V/0~300V(AUTO)
Output current4.2/2.18.4/4.216.8/8.425/12.542/2184/42126/63
Load regulation rate≤ 0.5%
harmonic distortion≤ 0.3%
Meter displayLED/LCD display voltage current frequency power (power factor)
Protection deviceOverload, overcurrent, temperature, short circuit, undervoltage protection and alarm
Working environmentAmbient temperature 0~40°C Relative humidity 10 ~ 90%

APA1000LSThree phase series

Model1006LS1010LS1015LS1020LS1030LS1045LS
Output capacity6KVA10KVA15KVA20KVA30KVA45KVA
Input1Ø2W+G 220V±10%

3Ø4W+G 220V/380V±10% 50/60Hz±5%

Output frequency50Hz 60Hz 45~500Hz
frequency stability0.01 percent
Output voltage0~150V/0~300V(AUTO)
Output current16.8/8.427.5/13.7542/2155.6/27.884/42126/63
Load regulation rate≤ 0.5%
harmonic distortion≤ 0.3%
Meter displayLED/LCD display voltage current frequency power (power factor)
Protection deviceOverload, overcurrent, overcurrent, temperature, short circuit, undervoltage and phase loss protection and alarm
Working environmentAmbient temperature 0~40°C Relative humidity 10 ~ 90%

Measurement function

ProjectResolution (4 bits)Accuracy
frequency table0.01Hz/0.1Hz Auto Range±0.1% reading±2c±0.05%/100Hz
voltmeter0.1V±0.2% reading±0.3% Full scale±2c±0.1%/100Hz
Ammeter1mA/10mA 10mA/100mA Auto Range±0.4% reading±0.3% Full scale±3c±0.1%/100Hz
power meter0.1W/1W 1W/10W 10W/100W Auto Range±0.2% reading±0.2% Full scale±5c(at50/60Hz)
±0.3% reading±0.2% Full scale±5c±0.1%/100Hz
power factor meter0.001± 0.001