parameters
• Input voltage range: single-phase 195~245V three-phase 340V ~ 420V
• Input frequency range: 50/60Hz ± 5%
• Output voltage range: single-phase 0~300V (0~600V optional) three-phase 0~520V (0~1040V optional)
• Output frequency range: 45~500Hz
distortion rate ≤ 0.3 voltage stabilization rate ≤ 0.5 frequency stability ≤ 0.01%
the three-phase phase angle can be adjusted (0~120). In use, each phase can independently adjust the voltage and frequency, and it can independently display the voltage and frequency linear climb and drop editing test functions. It can do the gradual change and interruption test of voltage and frequency, and has the independent compensation function of impedance, which can simulate various test and test grid power supplies.
• Low distortion interference, complete input/output isolation
• Single-phase maximum capacity up to 20KVA, three-phase power up to 60KVA
• Remote voltage feedback function to ensure that the test point voltage value is consistent with the set value
Voltage, current measurement using high-precision ADC AC sampling, digital true value calculation
• Using single chip microcomputer (D/A circuit) to directly collect voltage and current waveform data.
• With RS232 or RS485 interface, can communicate with the computer. A single machine can set up five groups of test groups, each group can set up 35 different test points (different voltage 0~300V, frequency 45~500Hz, time 0.1S ~ 999.9H setting) and can do (0~999999 times) cycle test
• Built-in soft start device, can easily start the motor, compressor and other high starting current load
• The use of central processor design, control the opening and closing of the logic circuit.
• Machine temperature, humidity detection, intelligent exhaust dehumidification, to ensure the normal use of power
humanized design
Large 7-inch touch screen displays various parameters: voltage, frequency, power, power, current, peak current, temperature, power, time, phase angle, impedance value and real-time curve of voltage and current
Power multi-point real-time sensor monitoring, normal operation code and fault code screen display, full control of power supply status
• Parameter calibration is completed by open software, which is different from other power supplies. Potentiometers and adjustable resistors are also adjusted on the circuit.
• Wide voltage and frequency adjustment range, digital key input, independent display of three-phase voltage and line voltage
Digital password lock, test data security and can prevent important test data from being modified by misoperation
APA2000L single phase series
Model | 2000L | 2001L | 2002L | 2003L | 2005L | 2010L | 2015L |
---|---|---|---|---|---|---|---|
Output capacity | 500VA | 1KVA | 2KVA | 3KVA | 5KVA | 10KVA | 15KVA |
Input | 1Ø2W+G 110V/220V±10% 50/60Hz±5% | ||||||
Output frequency | 50Hz/ 60Hz/ 45~500Hz | ||||||
frequency stability | 0.01 percent | ||||||
Output voltage | 0~150V/0~300V(AUTO) | ||||||
Output current | 4.2/2.1 | 8.4/4.2 | 16.8/8.4 | 25/12.5 | 42/21 | 84/42 | 126/63 |
Load regulation rate | ≤ 0.5% | ||||||
harmonic distortion | ≤ 0.3% | ||||||
Meter display | The touch screen displays real-time curves of voltage, frequency, power, power factor, current, peak current, temperature, power, time, phase angle, impedance value and voltage and current | ||||||
Protection device | Overload, overcurrent, temperature, short circuit, undervoltage protection and alarm | ||||||
Working environment | Ambient temperature 0~40°C Relative humidity 10 ~ 90% |
APA2000LS three phase series
Model | 2006LS | 2010LS | 2015LS | 2020LS | 2030LS | 2045LS |
---|---|---|---|---|---|---|
Output capacity | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA |
Input | 1Ø2W+G 220V±10% | 3Ø4W+G 220V/380V±10% 50/60Hz±5% | ||||
Output frequency | 50Hz/ 60Hz/ 45~500Hz | |||||
frequency stability | 0.01 percent | |||||
Output voltage | 0~150V/0~300V(AUTO) | |||||
Output current | 16.8/8.4 | 27.5/13.75 | 42/21 | 55.6/27.8 | 84/42 | 126/63 |
Load regulation rate | ≤ 0.5% | |||||
harmonic distortion | ≤ 0.3% | |||||
Meter display | The touch screen displays real-time curves of voltage, frequency, power, power factor, current, peak current, temperature, power, time, phase angle, impedance value and voltage and current | |||||
Protection device | Overload, overcurrent, overcurrent, temperature, short circuit, undervoltage and phase loss protection and alarm | |||||
Working environment | Ambient temperature 0~40°C Relative humidity 10 ~ 90% |