Aviation Power Supply Apa5000 Series (AC)
parameters
• LED/LCD display, clear and intuitive
• Higher power density, smaller size, lighter weight, space saving, easy to move
the protection level is as high as IP54, and the whole machine parts are treated with three defenses. Working temperature -40 ℃ ~ 50 ℃
• Available in both upright and trailer models for easy airport/hangar mobility or point use
• Super overload capability with optional extended overload function
• Meets MIL-STD-704,GJB181A,GJB572A
• More detailed protection function, can detect undervoltage/overvoltage, overcurrent, overload, over temperature, short circuit and other fault state
• internal temperature, humidity detection, to ensure the normal use of power
three-phase power supply can withstand three-phase unbalanced load: 120 ° +1 °;30% unbalanced load 120 ° +1.5 °;100 unbalanced load 120 ° +2 °
High performance characteristics
• Optional dual output, suitable for multiple load applications
• With emergency stop button, quick stop output
• With EF signal chain function
• Modular design, compact, smaller size, high power density, easier maintenance
APA5000 (AC) single-phase series
Model | 5000 | 5001 | 5002 | 5003 | 5005 | 5015 | 5020 | 5030 |
---|---|---|---|---|---|---|---|---|
Output capacity | 500VA | 1KVA | 2KVA | 3KVA | 5KVA | 15KVA | 20KVA | 30KVA |
Input | 1Ø2W+G 110V/220V±10% | 3Ø4W+G 220V/380V±10% | ||||||
50/60Hz ± 3Hz | ||||||||
Output frequency | Vertical/Trailer 300~500Hz 400Hz (Special Frequency Accepted Customization) | |||||||
Output voltage | 115V/220V 10% (special voltage accepts customization) resolution 0.1V accuracy 0.5%F.S.+4counts | |||||||
Output current | 4.2/2.1 | 8.4/4.2 | 16.8/8.4 | 25/12.5 | 42/21 | 126/63 | 168/84 | 250/125 |
Resolution 0.01A(500VA,1KVA) 0.1A (above 1KVA) Accuracy 0.2%F.S. +4counts | ||||||||
Load regulation rate | ≤ 1% (resistive load) | ≤ 1.5%(resistance) | ||||||
harmonic distortion | ≤ 2% (resistive load) | ≤ 3% (resistance) | ||||||
Meter display | LED/LCD Display | |||||||
Protection device | Input and output are equipped with fuse-free switch, overload, overcurrent, temperature, short circuit, overvoltage/undervoltage protection and alarm | |||||||
Overload capacity | 120%(1H)150%(1M)200%(15S) Other specifications are optional (based on 25% duty cycle test) | |||||||
Weight (kg) | 20 | 25 | 30 | 35 | 45 | 190 | 240 | 3500 |
Dimensions (mm) | 425*89*480 | 430*200*500 | 430*580*700 | 600*1260*700 | ||||
Working environment | Ambient temperature -40 ℃ ~ 50 ℃ Relative humidity 0 ~ 90% (non-condensing state) |
APA5000S (AC) three-phase series
Model | 5015S | 5020S | 5030s | 5045S | 5060S | 5075S | 5100S | 5120S |
---|---|---|---|---|---|---|---|---|
Output capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | 100KVA | 120KVA |
Input | 3Ø4W+G 220V/380V±15% | |||||||
50/60Hz ± 3Hz | ||||||||
Output frequency | 400Hz (trailer type)/300~500Hz (vertical type) resolution 0.01Hz accuracy ± 0.02 f. s. | |||||||
Output voltage | 115/200V ± 15V resolution 0.1V accuracy 0.5%F.S. +4counts | |||||||
Output current | 42/21 | 54/27 | 84/42 | 126/63 | 168/84 | 210/105 | 278/139 | 333/166 |
Resolution 0.1A Precision 0.5%F.S. +4counts | ||||||||
Load regulation rate | ≤ 1% (resistive load) | |||||||
harmonic distortion | ≤ 2% (resistive load) | |||||||
Meter display | LED/LCD Display | |||||||
Protection device | Overload, overcurrent, overtemperature, short circuit, overvoltage/undervoltage, phase loss protection and alarm | |||||||
Overload capacity | 125%(600S)150%(30S)200%(10S) Other specifications optional | |||||||
Weight (kg) | 210 | 230 | 270 | 360 | 450 | 540 | 600 | 800 |
Dimensions (mm) | 510*780*710 | 600*1260*700 | 750*1500*850 | 900*1780*950 | ||||
Working environment | Ambient temperature -40 ℃ ~ 50 ℃ Relative humidity 0 ~ 90% (non-condensing state) |