AC Purification Regulated Power Supply Apa6000 Series
parameters
• Input voltage range: 220V ± 15%/+ 10% ~-20% or 3 Ø3W + G 220V/380V/3 Ø4W + G 110V/190V 120/208V 220V/380V
load voltage stabilization rate ≦ 1% waveform distortion ≦ 3%
• Three-phase load unbalance within 30%, output voltage unbalance ≦ 3%. Full load can be used for a long time, overload within 30% can be short-term continuous voltage stabilization
High performance characteristics
High voltage regulation rate, small harmonic distortion, suitable for terminal equipment voltage regulation
• With purification capacity, the use of protection equipment in complex grid environment
It has slow start characteristics to prevent sudden wave damage of inductive load.
• No moving components, simple operation, maintenance-free, with RC loop, can eliminate IMPULSE and add surge absorber, prevent PULSE interference
• Pointed voltmeter, ammeter, accurate and intuitive
The operation mode is humanized, does not touch the strong electric part, and the panel key directly controls the power on and off, which is simple and safe.
• No noise source, quiet and comfortable environment
• Divided into A type (100/110V 60Hz),B type (200/220V 50Hz),C type (100/200V,110/220V,50Hz)
Applicable place
Computer center, industrial equipment, medical equipment, transaction equipment, home appliance automatic plug-in program machine, automatic test equipment, laboratory, inspection unit, communication equipment SMT equipment, OA equipment, CNC equipment, production line requirements equipment, etc.
APA6000 single-phase series
Model | 6005 | 6010 | 6015 | 6020 | 6030 | 6050 | |
---|---|---|---|---|---|---|---|
Capacity Capacity | 5KVA | 10KVA | 15KVA | 20KVA | 30KVA | 50KVA | |
Input Input | Voltage Voltage | Type A 110V Type B 220V Type C 110V 220V | |||||
Frequency Frequency | 50/60Hz ± 3Hz | ||||||
Range | 15%/+ 10% ~-20% | ||||||
Output Output | Voltage Voltage | Type A 100V 110V 120V Type B 200V 220V 240V Type C 100V/200V 110V/220V (isolated) | |||||
Voltage stabilization rate Regulation | ≦ 1% | ||||||
distortion rate Distortion | ≦ 3% | ||||||
Power factor | 0.8~1 | ||||||
Reaction time Response time | ≦ 0.5 weeks ~ 5 weeks to complete voltage stabilization ≦ 80ms | ||||||
Efficiency Efficiency | 90% to 95% | ||||||
Protection Protection | Short circuit and overload protection | ||||||
Working environment Working environment | Ambient temperature 0~40°C Relative humidity 10 ~ 90% |
APA6000S three-phase series
Model | 6015S | 6020S | 6030S | 6045S | 6060S | 6075S | |
---|---|---|---|---|---|---|---|
Capacity Capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | |
Input Input | Voltage Voltage | Type B 3Ø3W G 220V/380V Type C 3Ø4W G 110V/190V 120/208V 220V/380V | |||||
Frequency Frequency | 50/60Hz ± 3Hz | ||||||
Range | 15%/+ 10% ~-20% | ||||||
Output Output | Voltage Voltage | Type B 200V 220V 240V Type C 110V/190V 120/208V 220V/380V (isolated) | |||||
Voltage stabilization rate Regulation | ≦ 1% | ||||||
distortion rate Distortion | ≦ 3% | ||||||
Power factor | 0.8~1 | ||||||
Reaction time Response time | ≦ 0.5 weeks ~ 5 weeks to complete voltage stabilization ≦ 80ms | ||||||
Efficiency Efficiency | 90% to 95% | ||||||
Protection Protection | Short circuit and overload protection | ||||||
Working environment Working environment | Ambient temperature 0~40°C Relative humidity 10 ~ 90% |